Hyco Handyflow Oversink Vented Point of Use 5 litres – HF05LM

£82.85 Excl. VAT

Hyco Handyflow Oversink Vented Point of Use 5 litres – HF05LM

Part No                            Description

HF05LM                             Handyflow Oversink Vented Point of Use 5 litres

Usage:

Ideal for occasional use light dish washing at a single kitchen sink in the workplace, for example portable buildings, offices, shops, workshops, garages and other small commercial premises.

Features

• Open outlet heater to supply hot water to a single sink
• Ideal when economy and ease of installation are the key priorities
• Stylish design and slimline profile – depth only 7” (180mm)
• Comes complete with tap and chrome spout
• Thermal cut-out can be re-set rather than requiring to be replaced
• 2.0 kW element
• External temperature control with frost protection setting
• Neon element on indicator
• Wall fixing bracket included and cable pre-wired (1m) – saves time on installation
• No need for expansion vessel, relief valve or reducing valve

Technical Specification

Outer Casing
Easy clean, high impact plastic

Heating Element
Copper-sheathed type element

Thermostat
Capillary type adjustable to approx. 80⁰C
E setting approx. 55⁰C

Water Tank
Polypropylene

Insulation
High density polystyrene CFC free

Spout
Length 10” (250mm)

Safety
Open outlet non-pressurised system, supplied tap and spout must be used.

Safety re-settable thermal cut out. Frost protection setting when power is switched on.

Heating Cycle
It is normal for the spout on this type of unit to drip slightly during the heating cycle, caused by the water expanding as it heats up.

IP Rating
IP24

Installation
Must be sited above a sink using the wall fixing bracket supplied, with the spout and tap located at the bottom of the unit.

Plumbing
Must be installed by a suitably qualified person.

Minimum water pressure 0.3 bar.
Maximum water pressure 8.0 bar.

Water Connection
Inlet valve/tap 1 x 15mm compression.
Outlet 1 x chrome plated brass spray arm.
Fittings required (not supplied): none.

ONLY USE THE FITTINGS SUPPLIED SO THAT THE UNIT IS NOT PRESSURISED.

Electrical Connection
Installation must comply with current IEE regulations.

The product should be connected to the fixed wiring of the property via a double pole fused spur with a minimum break capacity of 13 amps.

Cable pre-wired (1m).

Approvals
CE

Standard Warranty
1 year parts or replacement warranty.

Data Tables

Product Code Capacity (litres) Power (kW) Heat Up TIme (mins) * Standing Loss (kWh/day)
HF05LM 5 2.0 12 0.32

* Heat up time from 10°C to 75°C

Product Code Height (mm) Width (mm) Depth (mm) Weight Empty (kg) Weight Full (kg)
HF05LM 400 270 180 3.5 8.2